Maximus Chillers Service, Maintenance and Repair to all Chillers

These compressors are hermetically sealed and therefore can be serviced. Reciprocating Compressors – These use pistons that pump a very small amount of refrigerant and extremely high pressures. Iam satisfied with the service provided by this Power cooling system service person at Shenoy nagar. The engineer who came for the service was very professional & very friendly behavior and completed the job clearly. The annual maintenance call was arranged at a time to suit me... I genuinely really enjoy my visits and calls with the Power Cooling Systems Company for our AC service & maintenance.

“It starts with age and reliability,” says Joe Leichner with Daikin Applied. “If the machines get to be 15, 18, or 20 years old and have had rough duty, it’s time to think about, ‘Is now the tipping point? Depending upon the market, the tolerance for reliability issues varies. But eventually, the time comes when most managers realize purchasing a new unit makes the most financial sense. Chiller manufacturers understand the financial ramifications of that decision, and they realize what the impact of purchasing one can have on maintenance budgets.

Our experienced and dedicated staff are always on hand to assist you with all industrial chiller needs. G) Wrap the temperature-sensitive package of the expansion valve in the recorded position and wrap it with insulation foam. C) Remove the temperature sensing package from the expansion valve and record its position.

The chilled water flow rate must be above 3 feet per second and below 12 feet per second. If the flow falls below 3 feet per second, your flow may become laminae. If the flow rises above 12 feet per second, vibration and noise lead to the ideal environment of tube erosion. These gasses can be produced chiller repair in a chiller on the low pressure side where there is a pump or filter. Because the evaporators operate in a vacuum, these non-condensable elements are able to leak in. These logs should include necessary information like flow rates, operating temperatures, pressures, and fluid levels.

In some parts of the refrigeration equipment of the Freon system, if there is oil leakage, oil dripping or oil traces, it can be determined that there is a leak of Freon refrigerant. I) assemble and weld the connecting tube of the gas-liquid separator, paying attention to the protection of nitrogen filling during the welding process. O) After completing the above process, two weeks later, check the system again to ensure that the condition and operation of the unit meet the design requirements. M) Allow the system to run for a further 48 hours, then take a small amount of compressor oil, check its taste and measure its acidity using pH paper, and replace the compressor oil if necessary. Before the industrial water chiller system is delivered to our customer for use, the entire system is commissioned. A properly serviced York® chiller can last for years of dependable service and make your experience with your York® chiller much more rewarding and satisfying by keeping costs down.